Portfolio piece

Sarnia, ON · commissioned 2018

Blue Mesa Solar

AC capacity
43.2 MW
DC capacity
55 MW
DC/AC ratio
1.27
PPA
$77/MWh
Hardware
12 inverters, 192 strings

Energy delivered

3.3 GWh

Jun 16 – 29, 2026

Performance index

98.7%

Actual ÷ expected while measured

Lost revenue

$3.6K

$3.6K recoverable

Clipped by inverters

3.8 MWh

A design choice (DC/AC ratio), not a fault

Wash or wait?

Based on the last 3 days (Jun 27 – 29, 2026) and the site's soiling station. A wash has to pay for itself before the next likely heavy rain or scheduled wash; type in a contractor's quote or your own window to change the answer.

$
days

Until the next likely heavy rain

Soiling station
99.9% clean
Last heavy rain (≥ 6 mm)
Jun 27 (2 days ago)
Soiling since
No soiling now
Will rain help?
Nothing to wash off
Soiling now
—
Pays back in
—
Net over 6 days
—
Verdict
Nothing to wash

No soiling above the noise floor in the last 3 days (Jun 27 – 29, 2026), so a wash wouldn't recover anything.

Other things to check

Nothing at Blue Mesa Solar above the noise floor.

Soiling and rain

What soiling cost each day, above what fell from the sky. Soiling that drops to zero after a heavy rain (6 mm or more) was washed off; soiling that carries on through one needs a crew.

Daily energy

This site's metered output against the physics model's expectation.

  • Expected (physics model)
  • Actual (metered)
0200 MWh400 MWh600 MWhJun 16Jun 19Jun 21Jun 24Jun 26Jun 29

Where the revenue went

Energy lost to each cause, priced at each site's PPA rate.

  • Inverter outage

    46.1 MWh

    $3.5K
  • Soiling

    335 kWh

    $26
  • CurtailmentNot recoverable

    0 kWh

    $0
  • String offline

    0 kWh

    $0
  • String degraded

    0 kWh

    $0

Underperforming strings

Below 93% of their siblings' output per kW, Jun 23 – 29, 2026.

No string is below 93% of its siblings in this window.

Inverters

The hardware at this site.

Inverters
InverterAC ratingDC capacityDC/ACStrings
Inverter 013.6 MW4.6 MW1.2716
Inverter 023.6 MW4.6 MW1.2716
Inverter 033.6 MW4.6 MW1.2716
Inverter 043.6 MW4.6 MW1.2716
Inverter 053.6 MW4.6 MW1.2716
Inverter 063.6 MW4.6 MW1.2716
Inverter 073.6 MW4.6 MW1.2716
Inverter 083.6 MW4.6 MW1.2716
Inverter 093.6 MW4.6 MW1.2716
Inverter 103.6 MW4.6 MW1.2716
Inverter 113.6 MW4.6 MW1.2716
Inverter 123.6 MW4.6 MW1.2716

Rendered from ClickHouse via GraphQL: 12 SQL queries reading 5.3M rows, 415 ms end to end (1133 ms of query time, some of it in parallel). How this works