Portfolio piece

Alamosa, CO · commissioned 2022

Prairie Crossing Solar

AC capacity
76 MW
DC capacity
89.4 MW
DC/AC ratio
1.18
PPA
$48/MWh
Hardware
19 inverters, 418 strings

Energy delivered

7.3 GWh

Jun 16 – 29, 2026

Performance index

99.6%

Actual ÷ expected while measured

Lost revenue

$1.6K

$1.6K recoverable

Clipped by inverters

658 kWh

A design choice (DC/AC ratio), not a fault

Wash or wait?

Based on the last 3 days (Jun 27 – 29, 2026) and the site's soiling station. A wash has to pay for itself before the next likely heavy rain or scheduled wash; type in a contractor's quote or your own window to change the answer.

$
days

Until the next likely heavy rain

Soiling station
99.9% clean
Last heavy rain (≥ 6 mm)
Jun 16 (13 days ago)
Soiling since
No soiling now
Will rain help?
Nothing to wash off
Soiling now
—
Pays back in
—
Net over 30 days
—
Verdict
Nothing to wash

No soiling above the noise floor in the last 3 days (Jun 27 – 29, 2026), so a wash wouldn't recover anything.

Other things to check

  • String offline: $102/day. Send a technician; the strings table below names which one.

Soiling and rain

What soiling cost each day, above what fell from the sky. Soiling that drops to zero after a heavy rain (6 mm or more) was washed off; soiling that carries on through one needs a crew.

Daily energy

This site's metered output against the physics model's expectation.

  • Expected (physics model)
  • Actual (metered)
0200 MWh400 MWh600 MWh800 MWhJun 16Jun 19Jun 21Jun 24Jun 26Jun 29

Where the revenue went

Energy lost to each cause, priced at each site's PPA rate.

  • String offline

    33.8 MWh

    $1.6K
  • Soiling

    190 kWh

    $9
  • Inverter outage

    0 kWh

    $0
  • CurtailmentNot recoverable

    0 kWh

    $0
  • String degraded

    0 kWh

    $0

Underperforming strings

Below 93% of their siblings' output per kW, Jun 23 – 29, 2026.

Underperforming strings
InverterStringOutput vs siblingsLikely cause
Inverter 10String 090%Offline (fuse or disconnect)
Inverter 05String 0212%Degraded

Inverters

The hardware at this site.

Inverters
InverterAC ratingDC capacityDC/ACStrings
Inverter 014 MW4.7 MW1.1822
Inverter 024 MW4.7 MW1.1822
Inverter 034 MW4.7 MW1.1822
Inverter 044 MW4.7 MW1.1822
Inverter 054 MW4.7 MW1.1822
Inverter 064 MW4.7 MW1.1822
Inverter 074 MW4.7 MW1.1822
Inverter 084 MW4.7 MW1.1822
Inverter 094 MW4.7 MW1.1822
Inverter 104 MW4.7 MW1.1822
Inverter 114 MW4.7 MW1.1822
Inverter 124 MW4.7 MW1.1822
Inverter 134 MW4.7 MW1.1822
Inverter 144 MW4.7 MW1.1822
Inverter 154 MW4.7 MW1.1822
Inverter 164 MW4.7 MW1.1822
Inverter 174 MW4.7 MW1.1822
Inverter 184 MW4.7 MW1.1822
Inverter 194 MW4.7 MW1.1822

Rendered from ClickHouse via GraphQL: 14 SQL queries reading 7.2M rows, 528 ms end to end (1247 ms of query time, some of it in parallel). How this works