Portfolio piece

Estevan, SK · commissioned 2019

Silver Bluff Solar

AC capacity
34.7 MW
DC capacity
40.8 MW
DC/AC ratio
1.18
PPA
$60/MWh
Hardware
11 inverters, 253 strings

Energy delivered

5.6 GWh

Jun 1 – 29, 2026

Performance index

98.5%

Actual ÷ expected while measured

Lost revenue

$5.1K

$11 recoverable

Clipped by inverters

0 kWh

A design choice (DC/AC ratio), not a fault

Communications were down for part of this period: 250 MWh of expected output went unmeasured and is left out of the performance index rather than counted as lost.

Wash or wait?

Based on the last 3 days (Jun 27 – 29, 2026) and the site's soiling station. A wash has to pay for itself before the next likely heavy rain or scheduled wash; type in a contractor's quote or your own window to change the answer.

$
days

Until the next likely heavy rain

Soiling station
99.8% clean
Last heavy rain (≥ 6 mm)
Jun 29 (today)
Soiling since
No soiling now
Will rain help?
Nothing to wash off
Soiling now
—
Pays back in
—
Net over 6 days
—
Verdict
Nothing to wash

No soiling above the noise floor in the last 3 days (Jun 27 – 29, 2026), so a wash wouldn't recover anything.

Other things to check

Nothing at Silver Bluff Solar above the noise floor.

Soiling and rain

What soiling cost each day, above what fell from the sky. Soiling that drops to zero after a heavy rain (6 mm or more) was washed off; soiling that carries on through one needs a crew.

Daily energy

This site's metered output against the physics model's expectation.

  • Expected (physics model)
  • Actual (metered)
0100 MWh200 MWh300 MWh400 MWhJun 1Jun 7Jun 12Jun 18Jun 23Jun 29

Where the revenue went

Energy lost to each cause, priced at each site's PPA rate.

  • CurtailmentNot recoverable

    85.5 MWh

    $5.1K
  • Soiling

    186 kWh

    $11
  • Inverter outage

    0 kWh

    $0
  • String offline

    0 kWh

    $0
  • String degraded

    0 kWh

    $0

Underperforming strings

Below 93% of their siblings' output per kW, Jun 23 – 29, 2026.

No string is below 93% of its siblings in this window.

Inverters

The hardware at this site.

Inverters
InverterAC ratingDC capacityDC/ACStrings
Inverter 013.2 MW3.7 MW1.1823
Inverter 023.2 MW3.7 MW1.1823
Inverter 033.2 MW3.7 MW1.1823
Inverter 043.2 MW3.7 MW1.1823
Inverter 053.2 MW3.7 MW1.1823
Inverter 063.2 MW3.7 MW1.1823
Inverter 073.2 MW3.7 MW1.1823
Inverter 083.2 MW3.7 MW1.1823
Inverter 093.2 MW3.7 MW1.1823
Inverter 103.2 MW3.7 MW1.1823
Inverter 113.2 MW3.7 MW1.1823

Rendered from ClickHouse via GraphQL: 11 SQL queries reading 5.8M rows, 416 ms end to end (1019 ms of query time, some of it in parallel). How this works