Portfolio piece

Abilene, TX · commissioned 2024

Iron Bluff Solar

AC capacity
47.5 MW
DC capacity
61.7 MW
DC/AC ratio
1.30
PPA
$36/MWh
Hardware
19 inverters, 418 strings

Energy delivered

4.7 GWh

Jun 16 – 29, 2026

Performance index

95.5%

Actual ÷ expected while measured

Lost revenue

$45

$45 recoverable

Clipped by inverters

157 MWh

A design choice (DC/AC ratio), not a fault

Wash or wait?

Based on the last 3 days (Jun 27 – 29, 2026) and the site's soiling station. A wash has to pay for itself before the next likely heavy rain or scheduled wash; type in a contractor's quote or your own window to change the answer.

$
days

Until the next likely heavy rain

Soiling station
99.9% clean
Last heavy rain (≥ 6 mm)
Jun 29 (today)
Soiling since
No soiling now
Will rain help?
Nothing to wash off
Soiling now
—
Pays back in
—
Net over 10 days
—
Verdict
Nothing to wash

No soiling above the noise floor in the last 3 days (Jun 27 – 29, 2026), so a wash wouldn't recover anything.

Other things to check

  • Irradiance sensor: output is 5.1% below the model, but the soiling station says the panels are clean and no equipment fault explains it. Most likely the pyranometer reads high (dirty dome or drifting calibration), so nothing is actually lost; check it before booking a wash.

Soiling and rain

What soiling cost each day, above what fell from the sky. Soiling that drops to zero after a heavy rain (6 mm or more) was washed off; soiling that carries on through one needs a crew.

Daily energy

This site's metered output against the physics model's expectation.

  • Expected (physics model)
  • Actual (metered)
0200 MWh400 MWh600 MWhJun 16Jun 19Jun 21Jun 24Jun 26Jun 29

Where the revenue went

Energy lost to each cause, priced at each site's PPA rate.

  • String degraded

    1.2 MWh

    $42
  • Soiling

    71 kWh

    $3
  • Inverter outage

    0 kWh

    $0
  • CurtailmentNot recoverable

    0 kWh

    $0
  • String offline

    0 kWh

    $0

Underperforming strings

Below 93% of their siblings' output per kW, Jun 23 – 29, 2026.

Underperforming strings
InverterStringOutput vs siblingsLikely cause
Inverter 03String 1672%Degraded

Inverters

The hardware at this site.

Inverters
InverterAC ratingDC capacityDC/ACStrings
Inverter 012.5 MW3.2 MW1.3022
Inverter 022.5 MW3.2 MW1.3022
Inverter 032.5 MW3.2 MW1.3022
Inverter 042.5 MW3.2 MW1.3022
Inverter 052.5 MW3.2 MW1.3022
Inverter 062.5 MW3.2 MW1.3022
Inverter 072.5 MW3.2 MW1.3022
Inverter 082.5 MW3.2 MW1.3022
Inverter 092.5 MW3.2 MW1.3022
Inverter 102.5 MW3.2 MW1.3022
Inverter 112.5 MW3.2 MW1.3022
Inverter 122.5 MW3.2 MW1.3022
Inverter 132.5 MW3.2 MW1.3022
Inverter 142.5 MW3.2 MW1.3022
Inverter 152.5 MW3.2 MW1.3022
Inverter 162.5 MW3.2 MW1.3022
Inverter 172.5 MW3.2 MW1.3022
Inverter 182.5 MW3.2 MW1.3022
Inverter 192.5 MW3.2 MW1.3022