Portfolio piece

Kingston, ON · commissioned 2020

Falcon Ridge Solar

AC capacity
37.5 MW
DC capacity
44.6 MW
DC/AC ratio
1.19
PPA
$74/MWh
Hardware
15 inverters, 285 strings

Energy delivered

3.3 GWh

Jun 16 – 29, 2026

Performance index

100.0%

Actual ÷ expected while measured

Lost revenue

$212

$212 recoverable

Clipped by inverters

24 kWh

A design choice (DC/AC ratio), not a fault

Wash or wait?

Based on the last 3 days (Jun 27 – 29, 2026) and the site's soiling station. A wash has to pay for itself before the next likely heavy rain or scheduled wash; type in a contractor's quote or your own window to change the answer.

$
days

Until the next likely heavy rain

Soiling station
99.9% clean
Last heavy rain (≥ 6 mm)
Jun 18 (11 days ago)
Soiling since
No soiling now
Will rain help?
Nothing to wash off
Soiling now
—
Pays back in
—
Net over 6 days
—
Verdict
Nothing to wash

No soiling above the noise floor in the last 3 days (Jun 27 – 29, 2026), so a wash wouldn't recover anything.

Other things to check

Nothing at Falcon Ridge Solar above the noise floor.

Soiling and rain

What soiling cost each day, above what fell from the sky. Soiling that drops to zero after a heavy rain (6 mm or more) was washed off; soiling that carries on through one needs a crew.

Daily energy

This site's metered output against the physics model's expectation.

  • Expected (physics model)
  • Actual (metered)
0100 MWh200 MWh300 MWh400 MWhJun 16Jun 19Jun 21Jun 24Jun 26Jun 29

Where the revenue went

Energy lost to each cause, priced at each site's PPA rate.

  • String degraded

    1.7 MWh

    $122
  • Soiling

    1.2 MWh

    $90
  • Inverter outage

    0 kWh

    $0
  • CurtailmentNot recoverable

    0 kWh

    $0
  • String offline

    0 kWh

    $0

Underperforming strings

Below 93% of their siblings' output per kW, Jun 23 – 29, 2026.

Underperforming strings
InverterStringOutput vs siblingsLikely cause
Inverter 04String 1073%Degraded

Inverters

The hardware at this site.

Inverters
InverterAC ratingDC capacityDC/ACStrings
Inverter 012.5 MW3 MW1.1919
Inverter 022.5 MW3 MW1.1919
Inverter 032.5 MW3 MW1.1919
Inverter 042.5 MW3 MW1.1919
Inverter 052.5 MW3 MW1.1919
Inverter 062.5 MW3 MW1.1919
Inverter 072.5 MW3 MW1.1919
Inverter 082.5 MW3 MW1.1919
Inverter 092.5 MW3 MW1.1919
Inverter 102.5 MW3 MW1.1919
Inverter 112.5 MW3 MW1.1919
Inverter 122.5 MW3 MW1.1919
Inverter 132.5 MW3 MW1.1919
Inverter 142.5 MW3 MW1.1919
Inverter 152.5 MW3 MW1.1919

Rendered from ClickHouse via GraphQL: 14 SQL queries reading 6.1M rows, 1117 ms end to end (3466 ms of query time, some of it in parallel). How this works