Portfolio piece

Alamosa, CO · commissioned 2017

Maple Valley Solar

AC capacity
72 MW
DC capacity
94.4 MW
DC/AC ratio
1.31
PPA
$47/MWh
Hardware
18 inverters, 432 strings

Energy delivered

7.3 GWh

Jun 16 – 29, 2026

Performance index

96.9%

Actual ÷ expected while measured

Lost revenue

$10.6K

$10.6K recoverable

Clipped by inverters

60.8 MWh

A design choice (DC/AC ratio), not a fault

Wash or wait?

Based on the last 3 days (Jun 27 – 29, 2026) and the site's soiling station. A wash has to pay for itself before the next likely heavy rain or scheduled wash; type in a contractor's quote or your own window to change the answer.

$
days

Until the next likely heavy rain

Soiling station
99.9% clean
Last heavy rain (≥ 6 mm)
Jun 24 (5 days ago)
Soiling since
No soiling now
Will rain help?
Nothing to wash off
Soiling now
—
Pays back in
—
Net over 30 days
—
Verdict
Nothing to wash

No soiling above the noise floor in the last 3 days (Jun 27 – 29, 2026), so a wash wouldn't recover anything.

Other things to check

Nothing at Maple Valley Solar above the noise floor.

Soiling and rain

What soiling cost each day, above what fell from the sky. Soiling that drops to zero after a heavy rain (6 mm or more) was washed off; soiling that carries on through one needs a crew.

Daily energy

This site's metered output against the physics model's expectation.

  • Expected (physics model)
  • Actual (metered)
0200 MWh400 MWh600 MWh800 MWhJun 16Jun 19Jun 21Jun 24Jun 26Jun 29

Where the revenue went

Energy lost to each cause, priced at each site's PPA rate.

  • Soiling

    225 MWh

    $10.6K
  • Inverter outage

    0 kWh

    $0
  • CurtailmentNot recoverable

    0 kWh

    $0
  • String offline

    0 kWh

    $0
  • String degraded

    0 kWh

    $0

Underperforming strings

Below 93% of their siblings' output per kW, Jun 23 – 29, 2026.

No string is below 93% of its siblings in this window.

Inverters

The hardware at this site.

Inverters
InverterAC ratingDC capacityDC/ACStrings
Inverter 014 MW5.2 MW1.3124
Inverter 024 MW5.2 MW1.3124
Inverter 034 MW5.2 MW1.3124
Inverter 044 MW5.2 MW1.3124
Inverter 054 MW5.2 MW1.3124
Inverter 064 MW5.2 MW1.3124
Inverter 074 MW5.2 MW1.3124
Inverter 084 MW5.2 MW1.3124
Inverter 094 MW5.2 MW1.3124
Inverter 104 MW5.2 MW1.3124
Inverter 114 MW5.2 MW1.3124
Inverter 124 MW5.2 MW1.3124
Inverter 134 MW5.2 MW1.3124
Inverter 144 MW5.2 MW1.3124
Inverter 154 MW5.2 MW1.3124
Inverter 164 MW5.2 MW1.3124
Inverter 174 MW5.2 MW1.3124
Inverter 184 MW5.2 MW1.3124

Rendered from ClickHouse via GraphQL: 12 SQL queries reading 7.3M rows, 471 ms end to end (1256 ms of query time, some of it in parallel). How this works